10. INTERFACE SIGNALS
B–65162E/03
396
(2) 2nd Spindle Signal Address
FS0
FS0–TT
HEAD2
FS15 FS16 #7 #6 #5 #4 #3 #2 #1 #0
F281 F1481 F229 F045 ORARB
TLMB LDTB SARB SDTB SSTB ALMB
(3) Spindle control DO signals
Symbol Signal Description
ALMA, B Alarm signal
Output when a spindle alarm occurs.
0 : Normal state
1 : Alarm state
SSTA, B
Frequency stop
detection signal
Output when the output frequency of actual spindle amplifier
module becomes lower than the frequency stop detection
level.
0 : Rotation state
1 : Frequency stop
SDTA, B
Frequency
detection signal
Output when the output frequency of actual spindle amplifier
module does not exceed the preset amplifier frequency.
0 : Higher than the specified speed
1 : Less than preset frequency
SARA, B
Frequency
match signal
Output when the output frequency of actual spindle amplifier
module reaches the preset range.
0 : Specified speed has yet to be reached
1 : Frequency match
LDTA, B
Load detection
signal
Output when the detected load is greater than the specified
load detection level.
0 : Lower than the specified load
1 : Greater than the specified load
TLMA, B
Torque limiting
signal (Under
development)
1 : The limit is applied to the torque.
ORARA, B
Orientation
complete signal
Output when orientation was specified and the spindle has
stopped in the specified range.
1 : Orientation completed
R12O-R01O
RO15-RO00
Spindle speed
command
Outputs the spindle speed command.
MF
M function
strobe signal
1 : The M code is effective.
SF
Spindle func-
tion strobe sig-
nal
1 : The S code is effective.
ENB
Spindle enable
signal
0 : The velocity command indicates 0.
1 : The velocity command indicates other than 0.
SPAL
Spindle fluctua-
tion alarm sig-
nal
1 : The actual speed of the spindle is out of the allowed
range.
SPAO,
SPBO SPCO
Spindle speed
override check
signal
GR10, 20, 30
Gear select
signal