B–65162E/03
9.CONNECTION
215
– Cable K3 for combining the PSMR and the SPM–11 (with a fan adapter)
200S
200R
CX1A
(3)
(2)
(1)
SPM
–11
350/X
Cable specification: Two–conductor polyvinyl heavy–duty power cable (JIS C3312),
conductor size of 1.25 mm
2
(50/0.18), PVC sheath 9.6 mm in diameter
Connector specification: AMP connector with receptacle housing 1–178128–3 and
receptacle contact 1–175218–2
Control power
200 VAC,
50/60 Hz single–phase
S
R
NOTE
If the PSMR is combined with the SPM–11 (with a fan adapter), the position at which cable K3 is
connected differs from other combinations. See the connection diagram under ”Power supply
module (PSMR); connected with the SPM–11 (with a fan adapter)” in Section 9.2.1 for details.
(4) Detailed description of the connection of cable K4
Cable K4 is used to supply power to the cooling fan of a module. Use this
cable to connect the power supply module to a spindle amplifier module
or servo amplifier module having a built–in cooling fan (see below).
Modules to be connected using cable K4
SPM–11 (required only when TYPE 3 or a fan adapter is used)
SPM–15 to SPM–30
SPM–11HV (required only when a fan adapter is used)
SPM–15HV to SPM–45HV
SVM1–240 and SVM1–360
200S
200R
PSM
CX1B
(3)
(2)
(1)
350/X
CX1A
(3)
(2)
(1)
SPM
350/X
Cable specification: Two–conductor polyvinyl heavy–duty power cable
(JIS C3312), conductor size of 1.25 mm
2
(50/0.18),
PVC sheath 9.6 mm in diameter
Connector specification: AMP connector with receptacle housing 1–178128–3 and
receptacle contact 1–175218–2