B–65162E/03
2. CONFIGURATION AND ORDERING INFORMATION
41
– Recommended parts
Parts manufactured by Fuji Electric Co., Ltd.
PSM name Circuit breaker 1 Circuit breaker 2 Circuit breaker 2 Magnetic contactor Remarks
PSM–5.5 EA103B/50 SC–1N
PSM–11 EA103B/60
SC–2N
PSM–15 EA103B/75 SC–2SN
PSM–26 EA203B/150 SC–4N
PSM–30 EA203B/150
EA33/5 –
SC–5N
PSM–37 EA203B/175 SC–7N
PSM–45 EA203B/225 SC–8N
PSMR–3 EA53B/30 SC–5–1
PSMR–5.5 EA103B/50 SC–1N
PSM–18HV EA103B/50 SC–1N
PSM–30HV EA103B/75
SC–2SN
PSM–45HV EA203B/125
SC–4N
PSM–75HV EA203B/200 SC–7N
PSMV–11HV – EA33/5 EA33/5 SC–2N
NOTE
For details, see the brochures available from Fujitsu Electric Co., Ltd. Note that the
specification of the coil voltage of a magnetic contactor may differ depending on the supply
voltage and frequency used.
(11) Lightning surge protector
To protect equipment from surge voltages caused by lightning, install a lightning surge protector between lines and
between a line and ground. For how to install protectors, see Appendix A. For the outline drawings of lightning surge
protectors, see Section 8.1.11.
Category Ordering number Specification Outline drawing Remarks
p
A06B–6077–K142
For line–to–line installation:
RAV–781BYZ–2
For line–to–ground installation:
RAV–781BXZ–4
Fig. 8.1.11 (a)
AC200V
For 200–VAC line
(Note 1)
A06B–6077–K143
For line–to–line installation:
RAV–152BYZ–2A
For line–to–ground installation:
RAV–801BXZ–4
Fig. 8.1.11 (b)
AC400V
For 400–VAC line
(Note 2)