B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 123 -
NOTE
This method does not apply if the distance from the
zero point of the encoder to the reference position
exceeds 99,999,999.
1885 Maximum allowable value for total travel during torque control
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] 0 to 32767
This parameter sets the maximum allowable value for the total travel
(error counter value) for an axis placed under torque control, as
specified by the axis control command of the PMC axis control
function. If the total travel exceeds the parameter-set value while
torque control is applied, a servo alarm (No.423) is generated.
NOTE
This parameter is enabled when the TQF
parameter (bit 4 of parameter No.1803) is 0
(follow-up is not performed during torque control).
1886 Positional deviation when torque control is canceled
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] 0 to 32767
This parameter sets the positional deviation used when torque control,
performed for an axis according to the axis control command of the
PMC axis control function, is canceled and position control is
resumed. After the positional deviation has fallen to the parameter-set
value, switching to position control is performed.
NOTE
This parameter is enabled when the TQF
parameter (bit 4 of parameter No.1803) is 0
(follow-up is not performed during torque control).