B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 275 -
4.24 PARAMETERS OF SCALING/COORDINATE ROTATION
#7 #6 #5 #4 #3 #2 #1 #0
5400
SCR XSC RCW RIN
[Data type] Bit
RIN Coordinate rotation angle command (R)
0 : Specified by an absolute method
1 : Specified by G90 or G91
NOTE
For the G code system A (T series), this parameter
is invalid.
RCW When a workpiece or local coordinate system command is issued in
coordinate system rotation mode:
0 : No alarm is issued.
1 : An alarm (P/S alarm No. 5302) is issued.
XSC Scaling mirror image for each axis in scaling is:
0 : Disabled. (The scaling magnification common to all axes is
specified with P.)
1 : Enabled. (The scaling magnification for each axis is specified
with I, J, and K.)
SCR Scaling magnification unit
0 : 0.00001 times (1/100,000)
1 : 0.001 times
#7 #6 #5 #4 #3 #2 #1 #0
5401 SCLx
[Data type] Bit axis
SCLx Scaling
0 : Invalidated
1 : Validated
#7 #6 #5 #4 #3 #2 #1 #0
5402
S8D
[Data type] Bit axis
S8D The unit of scaling magnification is:
0 : Dependent on the setting of bit 7 (SCR) of parameter No. 5400.
1 : 0.0000001 (1/10,000,000).