B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 289 -
1 : Called using a T code
CCV Custom macro's common variables Nos. 100 to 199
0: Cleared to "vacant" by reset
1: Not cleared by reset
CLV Custom macro's local variables Nos. 1 to 33
0: Cleared to "vacant" by reset
1: Not cleared by reset
#7 #6 #5 #4 #3 #2 #1 #0
6003 MUS MCY MSB MPR TSE MIN MSK
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Bit
MSK Absolute coordinates at that time during custom macro interrupt
0 : Not set to the skip coordinates (system variables #5061 and later)
1 : Set to the skip coordinates (system variables #5061 and later)
MIN Custom macro interrupt
0 : Performed by interrupting an in-execution block (Custom macro
interrupt type I)
1 : Performed after an in-execution block is completed (Custom
macro interrupt type II)
TSE Custom macro interrupt signal UINT <G053#3>
0 : Edge trigger method (Rising edge)
1 : Status trigger method
MPR Custom macro interrupt valid/invalid M code
0 : M96/M97
1 : M code set using parameters (Nos. 6033 and 6034)
MSB Interrupt program
0 : Uses a dedicated local variable (Macro-type interrupt)
1 : Uses the same local variable as in the main program
(Subprogram- type interrupt)
MCY Custom macro interrupt
0 : Not performed during cycle operation
1 : Performed during cycle operation
MUS Interrupt-type custom macro
0 : Not used
1 : Used