B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 305 -
4.33 PARAMETERS OF EXTERNAL DATA INPUT/OUTPUT
#7 #6 #5 #4 #3 #2 #1 #0
6300 EEX ESR ESC
[Data type] Bit
ESC When a reset is input between input of the external data input read
signal ESTB <G002#7> and execution of a search, the external
program number search function:
0 : Performs a search.
1 : Does not perform a search.
ESR External program number search
0 : Disabled
1 : Enabled
EEX PMC EXIN function
0 : Conventional specifications
1 : Extended specifications
If you want to handle data unavailable with the PMC/EXIN command
according to the conventional specifications, such as an 8-digit
program number, in an external program number search, set this bit to
1.
To use this function for multipath control, the setting for the first path
(main) is used. The EXIN specifications cannot be changed for each
path. For details of EXIN and how to change ladder software, refer to
the PMC specifications and other manuals.
6310 Number of added message numbers of external operator messages
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Word
[Valid data range] 0, 1 to 1000
For external operator messages within the range set in this parameter,
message numbers each obtained by adding 2000 to the relevant
message number are indicated.
NOTE
If 0 or a value beyond the valid data range is set in
this parameter, this parameter becomes invalid.