B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 343 -
4.44 PARAMETERS OF GENERAL-PURPOSE RETRACTION
#7 #6 #5 #4 #3 #2 #1 #0
7704
ACR
[Data type] Bit
ACR In advanced preview control, AI advanced preview control, or AI
contour control mode, the general-purpose retraction function is:
0 : Not used.
1 : Used.
(See the description of parameter No. 7745.)
#7 #6 #5 #4 #3 #2 #1 #0
7730 RTRx
[Data type] Bit axis
RTRx Retraction function is:
0 : Disabled for each axis.
1 : Enabled for each axis.
7740 Feedrate during retraction for each axis
[Data type] 2-word axis
[Unit of data, valid data range]
Valid data range
Increment system Units of data
IS-B IS-C
Millimeter machine 1 mm/min 30 to 240000 6 to 100000
Inch machine 0.1 inch/min 30 to 96000 6 to 48000
This parameter sets the feedrate during retraction for each axis.
7741 Retracted distance for each axis
[Data type] 2-word axis
Unit of data
Increment system
IS-B IS-C
Millimeter input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
[Valid range] -99999999 to 99999999
This parameter sets the retracted distance for each axis.