4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 76 -
1460
Upper limit of feedrate for the one-digit F code command (F1 to F4)
1461
Upper limit of feedrate for the one-digit F code command (F5 to F9)
[Data type] 2-word
[Unit of data, valid data range]
Valid data range
Increment system Unit of data
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Rotation axis 1 deg/min 6 to 15000 6 to 12000
Set the upper limit of feedrate for the F1-digit feed command.
As the feedrate increases by turning the manual pulse generator, the
feedrate is clamped when it reaches the upper limit set. If an F1-digit
feed command F1 to F4 is executed, the upper limit is that set in
parameter 1460. If an F1-digit command F5 to F9 is executed, the
upper limit is that set in parameter 1461.