4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 376 -
4.54 PARAMETERS OF MANUAL HANDLE FUNCTION
12305 Address of the X signal for first manual handle
12306 Address of the X signal for second manual handle
12307 Address of the X signal for third manual handle
[Data type] Word
[Valid data range] 0 to 127, 200 to 327
These parameters set the address of the X signal used for each manual
handle.
These parameters are valid when bit 1 (HDX) of parameter No.7105 is
set to 1.
If the address assigned to a manual handle of an I/O module connected
to the I/O Link is not set correctly, the manual handle does not
function.
#7 #6 #5 #4 #3 #2 #1 #0
12330 GR7 GR6 GR5 GR4 GR3 GR2 GR1 GR0
12331 GRF GRE GRD GRC GRB GRA GR9 GR8
[Data type] Bit
GR0 When group 0 (channel 1) of the PMC is a Power Mate or I/O Link β,
pulses of a manual pulse generator connected via the I/O Link are:
0 : Transferred to the target group.
1 : Not transferred to the target group.
GR1 to GRD When group 1 (channel 1) of the PMC is a Power Mate or I/O Link β,
pulses of a manual pulse generator connected via the I/O Link are:
0 : Transferred to the target group.
1 : Not transferred to the target group.
GRE When group 14 (channel 1) of the PMC is a Power Mate or I/O Link β,
pulses of a manual pulse generator connected via the I/O Link are:
0 : Transferred to the target group.
1 : Not transferred to the target group.
GRF When group 15 (channel 1) of the PMC is a Power Mate or I/O Link β,
pulses of a manual pulse generator connected via the I/O Link are:
0 : Transferred to the target group.
1 : Not transferred to the target group.
NOTE
When a Power Mate is connected to the I/O Link,
set this parameter to 1.