4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 368 -
4.50 OTHER PARAMETERS
#7 #6 #5 #4 #3 #2 #1 #0
8700 DMM
[Data type] Bit
DMM In DNC operation from the PMC, OPEN CNC, or C-EXE, pre-reading
is:
0 : Not performed.
1 : Performed.
#7 #6 #5 #4 #3 #2 #1 #0
8701 WPR
[Data type] Bit
WPR The function that allows parameters that are rewritten using the PMC
window to be enabled during automatic operation is:
0 : Disabled.
1 : Enabled.
NOTE
If this parameter is set, a move command based on
manual operation is disabled (interlock state) while
parameter rewriting using the PMC window is being
executed.
#7 #6 #5 #4 #3 #2 #1 #0
8702 LFM SME
[Data type] Bit
SME During DNC operation or M198 call, parameter No. 8790 (timing for
executing an auxiliary macro) is:
0 : Invalid.
1 : Valid.
LFM At the beginning of program uploading in response to a request using
the data window library:
0 : "LF+%" is not output.
1 : "LF+%" is output.
#7 #6 #5 #4 #3 #2 #1 #0
8703 WSP
[Data type] Bit
WSP When serial spindle parameter Nos. 4000 to 4799 are rewritten with
function code 18 (parameter write) of the PMC window function, the
new data is:
0 : Not transferred to the spindle amplifier immediately.
1 : Transferred to the spindle amplifier immediately.