4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 178 -
4.19 PARAMETERS OF PITCH ERROR COMPENSATION
#7 #6 #5 #4 #3 #2 #1 #0
3605 ROPx BDPx
NOTE
When this parameter has been set, the power must
be turned off before operation is continued.
[Data type] Bit
BDPx Both-direction pitch error compensation is:
0 : Not used.
1 : Used.
NOTE
The function of both-direction pitch error
compensation is required.
ROPx The interval of pitch error compensation for a rotation axis (type A) is:
0 : Restricted by the following equation:
Minimum value = maximum feedrate (rapid traverse rate)/7500.
1 : Not restricted by the following equation:
Minimum value = maximum feedrate (rapid traverse rate)/7500.
3620
Number of the pitch error compensation position for the reference position
for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Word axis
[Unit of data] Number
[Valid data range] 0 to 1023
Set the number of the pitch error compensation position for the
reference position for each axis.
3
2
1
-1
-2
Pitch error compensation value (absolute value)
Reference position
Pitch error compensation
position (number)
Compensation position number
Set compensating value
31 32 33 34 35 36 37
-3 +1 +1 +1 +2 -1 -3