B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 327 -
#7 #6 #5 #4 #3 #2 #1 #0
7053
AIP
NOTE
When this parameter has been set, the power must
be turned off before operation is continued.
[Data type] Bit
AIP In AI contour control, a stroke limit check before movement is:
0 : Disabled.
1 : Enabled.
NOTE
The stroke limit check before movement must be
enabled (by setting bit 7 (PLC) of parameter No.
1301 to 1).
#7 #6 #5 #4 #3 #2 #1 #0
7054
AIL AZR FNS AIR
[Data type] Bit
AIR In AI advanced preview control mode or AI contour control mode, the
rapid traverse type is:
0 : Linear interpolation type positioning (acceleration/deceleration
before interpolation is performed).
1 : According to the setting of bit 1 (LRP) of parameter No. 1401.
FNS When an S code is specified in AI advanced preview control or AI
contour control mode, execution of a move command in the same
block as the block specifying the S code is:
0 : Decelerated to stop once.
1 : Not decelerated to stop.
AZR In AI advanced preview control mode or AI contour control mode, the
G27, G28, G30, G30.1, and G53 commands are executed:
0 : In normal mode. (advanced preview feed forward is valid.)
1 : In AI contour control mode.
AIL When non-linear type positioning is specified in AI advanced preview
control mode or AI contour control mode and an axis-by-axis
interlock signal is input:
0 : The tool stops along all axes.
1 : The setting of bit 4 (XIK) of parameter No. 1002 is used.