B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 141 -
3012 Address to be assigned to skip signals
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Word
[Valid data range] 0 to 127
Set the address to which the skip signals (SKIPn), measurement
position arrival signals (XAE, YAE (for the M series only), and ZAE),
and manual feed interlock signal for each axis direction and tool
compensation amount write signal (±MIT1 (for the T series only) and
±MIT2 (for the T series only)) are assigned.
This parameter is valid when bit 2 (XSG) of parameter No. 3008 is set
to 1.
3013 Address to be assigned to reference position return deceleration signals
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Word axis
[Valid data range] 0 to 127
Set the address to which the reference position return deceleration
signal for each axis (*DECn) is assigned.
This parameter is valid when bit 2 (XSG) of parameter No. 3008 is set
to 1.
3014 Bit position to be assigned to reference position return deceleration signals
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Byte axis
[Valid data range] 0 to 7
Set the bit position to which the reference position return deceleration
signal for each axis (*DECn) is assigned. Set the address in parameter
No. 3013.
This parameter is valid when bit 2 (XSG) of parameter No. 3008 is set
to 1.