4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 198 -
3736
Maximum clamp speed of the spindle motor
[Data type] Word
[Valid data range] 0 to 4095
Set the maximum clamp speed of the spindle motor.
Maximum clamp speed of the spindle motor
Set value=
Maximum spindle motor speed
×4095
NOTE
If the function of constant surface speed control or
bit 4 (GTT) of parameter No. 3706 is specified, this
parameter is invalid.
In this case, the maximum clamp speed of spindle
motor cannot be specified. However, the maximum
spindle speed can be specified by the following
parameters.
Parameter No.3772 (for the first axis)
Parameter No.3802 (for the second axis)
Parameter No.3882 (for the third axis)
Spindle motor speed
Max. speed (4095, 10V)
Spindle motor max. clamp
speed (Parameter No.3736)
Spindle motor minimum clamp
speed (Parameter No.3735)
Spindle speed (S command)
Fig.4.20 (a) Maximum Clamp Speed of Spindle Motor
3740 Time elapsed prior to checking the spindle speed arrival signal
[Data type] Byte
[Unit of data] msec
[Valid data range] 0 to 225
Set the time elapsed from the execution of the S function up to the
checking of the spindle speed arrival signal.