B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 127 -
NOTE
When automatic setting mode is selected for FSSB
setting (when the FMD parameter (bit 0 of
parameter No.1902) is set to 0), parameter
No.1905 is automatically set when input is
performed with the FSSB setting screen. When
manual setting 2 mode is selected for FSSB setting
(when the FMD parameter (bit 0 of parameter
No.1902) is set to 1), parameter No.1905 must be
set directly. When a separate detector interface
unit is used, a connector number must be set in the
corresponding parameter (No.1936 or No.1937).
1910 Address conversion table value for slave 1 (ATR)
1911 Address conversion table value for slave 2 (ATR)
1912 Address conversion table value for slave 3 (ATR)
1913 Address conversion table value for slave 4 (ATR)
1914 Address conversion table value for slave 5 (ATR)
1915 Address conversion table value for slave 6 (ATR)
1916 Address conversion table value for slave 7 (ATR)
1917 Address conversion table value for slave 8 (ATR)
1918 Address conversion table value for slave 9 (ATR)
1919 Address conversion table value for slave 10 (ATR)
NOTE
After these parameters have been set, the power
must be turned off then back on for the settings to
become effective.
[Data type] Byte
[Valid data range] 0 to 3, 16, 40, 48
These parameters set address conversion table values for slaves 1 to
10.
A slave is the generic name given to a device such as a servo
amplifier or separate detector interface unit, connected to the CNC via
an FSSB optical cable. Smaller numbers, starting from 1 are assigned
to slaves closer to the CNC; the maximum number that can be
assigned is 10. A two-axis amplifier has two slaves, while a three-axis
amplifier has three slaves. Set each parameter as described below,