4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 374 -
4.52 PARAMETERS OF MAINTENANCE
#7 #6 #5 #4 #3 #2 #1 #0
8901 FAN
[Data type] Bit
FAN A fan motor error is:
0 : Detected. (When the fan motor error is detected, an overheating
alarm occurs.)
1 : Not detected. (Use inhibited)
#7 #6 #5 #4 #3 #2 #1 #0
8903 PRM
[Data type] Bit
PRM A periodic maintenance expiration message is:
0 : Not displayed.
1 : Displayed.
8911 Ratio of the items on the periodic maintenance screen to the respective lives
[Data type] Byte
[Unit of data] 1%
[Valid data range] 0 to 100
On the periodic maintenance screen, if the remaining time of an item
falls to a value less than the percentage of the life specified in this
parameter, the remaining time is displayed in red as a warming.
8940 Title character code 1
8941 Title character code 2
:
8949 Title character code 10
[Data type] Byte
[Valid data range] See below.
When the CNC is turned on, up to ten characters specified in these
parameters are displayed on the screen showing the series and edition
of the CNC.
• The following characters can be used.
0 to 9, A to Z, - (minus sign), . (period), and space
• The character codes to be specified are listed in the character
code list in Appendix A.
• If any code other than those character codes that can be specified
is specified, a space is displayed.