B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 41 -
#7 #6 #5 #4 #3 #2 #1 #0
DWT WIC SVS ZRL RHR
1015
DWT WIC ZRL RHR
[Data type] Bit
RHR After increment system (inch/metric) switching, for the rotation axis,
the first G28 command causes reference position return:
0 : At a low speed.
1 : At a high speed/
ZRL For high-speed reference position return according to G28, second to
fourth reference position return according to G30, and G53 command:
0 : Non-linear type positioning is performed.
1 : Linear type positioning is performed.
This parameter is valid when bit 1 (LRP) of parameter No. 1401 is set
to 1.
SVS When the servo along an axis is turned off, simple synchronous
control is:
0 : Released.
1 : Not released.
WIC Direct input of measured values for workpiece origin offsets is:
0 : Enabled only in a selected workpiece coordinate system.
1 : Enabled in all coordinate systems.
NOTE
If this parameter is set to 0, measured values can
be input directly only in the currently selected
workpiece coordinate system or external workpiece
coordinate system. If a measured value is input
directly for a workpiece origin offset in another
coordinate system, a warning is issued.
DWT When a dwell time is specified with P, the unit of data is:
0 : 1 ms for IS-B, or 0.1 ms for IS-C.
1 : 1 ms. (Not depending on the increment system.)
1020 Program axis name for each axis
[Data type] Byte axis
Set the program axis name for each controlled axis, using one of the
values listed in the following table:
Axis
name
Setting Axis
name
Setting Axis
name
Setting Axis
name
Setting
X 88 U 85 A 65 E 69
Y 89 V 86 B 66 - -
Z 90 W 87 C 67 - -