B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 161 -
NOTE
If this parameter is set, a protected program is also
displayed.
#7 #6 #5 #4 #3 #2 #1 #0
3203 MCL MER MIE
[Data type] Bit
MIE After MDI operation is started, program editing during operation is:
0 : Enabled
1 : Disabled
MER When the last block of a program has been executed at single block
operation in the MDI mode, the executed block is:
0 : Not deleted
1 : Deleted
NOTE
When MER is set to 0, the program is deleted if the
end-of-record mark (%) is read and executed. (The
mark % is automatically inserted at the end of a
program.)
MCL Whether a program prepared in the MDI mode is cleared by reset
0 : Not deleted
1 : deleted
#7 #6 #5 #4 #3 #2 #1 #0
3204 MKP EXK PAR
[Data type] Bit
PAR When a small keyboard is used, characters "[" and "]" are:
0 : Used as "[" and "]".
1 : Used as "(" and ")".
EXK The input character extension function is:
0 : Not used. ([C-EXT] soft key is displayed.)
1 : Used.
NOTE
The [C-EXT] soft key is used to select an operation
on the program screen. This soft key enables the
entry of "(", ")", and "@" using soft keys. This soft
key is useful when using the small MDI keyboard,
which does not have the "(", ")", and "@" keys.
MKP When M02, M30, or EOR(%) is executed during MDI operation, the
created MDI program is:
0 : Erased automatically.
1 : Not erased automatically.