B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 349 -
[Data type] Bit
EML When bit 0 (MLE) of parameter No. 8001 is set to 1, for PMC axes:
0 : The all axis machine lock signal and axis-by-axis machine lock
signals are disabled.
1 : The all axis machine lock signal is disabled and the axis-by-axis
machine lock signals are enabled.
IPA For controlled axis at PMC axis control only (see the parameter
No.1010) :
0 : The in-position check is performed when no move command is
issued for the PMC axis.
1 : No in-position check is always performed.
EZR For PMC axes, the setting of bit 0 (ZRN) of parameter No. 1005 is:
0 : Not followed. (Constant checking of the reference position return
status is not made.)
1 : Followed. (The reference position return status is checked
according to the setting of bit 0 (ZRN) of parameter No. 1005.)
EAL In axis control by the PMC, the function that allows the alarm signal
(EIALg) to be reset by a CNC reset operation is:
0 : Disabled.
1 : Enabled.
#7 #6 #5 #4 #3 #2 #1 #0
8007 NIS
[Data type] Bit
NIS In the in-position check of PMC axes, in-position check disable signal
NOINPS <G023#5> and in-position check disable signals for
individual axes NOINP1 to NOINP8 <G359> are:
0 : Invalid.
1 : Valid.
NOTE
Although in-position checks of ordinary blocks can
be disabled by using in-position check disable
signal NOINPS <G023#5> and in-position check
disable signals for individual axes NOINP1 to
NOINP8 <G359>, the in-position check at the
reference position obtained by a reference position
return operation (G28 or G30) is always performed.
The in-position check at an intermediate point,
however, can be disabled. To disable the
in-position check at the reference position as well,
set bit 0 (RF2) of parameter No. 3454 to 1, and
specify a reference position return by using G28.2
or G30.2.
#7 #6 #5 #4 #3 #2 #1 #0
8008 MIRx
[Data type] Bit axis