4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 166 -
#7 #6 #5 #4 #3 #2 #1 #0
3290 KEY MCM IWZ WZO MCV GOF WOF
[Data type] Bit
WOF Setting the tool offset value by MDI key input is:
0 : Not disabled
1 : Disabled (With parameter No.3294 and No.3295, set the offset
number range in which updating the setting is to be disabled.)
GOF Setting the tool offset value by MDI key input is:
0 : Not disabled
1 : Disabled (With parameter No.3294 and No.3295, set the offset
number range in which updating the setting is to be disabled.)
MCV Macro variable setting by MDI key input is:
0 : Not disabled
1 : Disabled
NOTE
If this parameter is set to 1, input of tool life
management data by MDI is also disabled.
WZO Setting a workpiece zero point offset value by MDI key input is:
0 : Not disabled
1 : Disabled
IWZ Setting a workpiece zero point offset value or workpiece shift value
(T-series) by MDI key input in the automatic operation activation or
halt state is:
0 : Not disabled
1 : Disabled
MCM The setting of custom macros by MDI key operation is:
0 : Enabled regardless of the mode.
1 : Enabled only in the MDI mode.
KEY For memory protection keys:
0 : The KEY1, KEY2, KEY3, and KEY4 signals are used.
1 : Only the KEY1 signal is used.