4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 20 -
Set the number specified for the input/output device used when I/O
CHANNEL is set to 2, with a value in Table 4.2.2 (a).
0123 Baud rate (when the I/O CHANNEL is set to 2)
[Data type] Byte
Set the baud rate of the input/output device used when I/O
CHANNEL is set to 2, with a value in Table 4.2.2 (b).
#7 #6 #5 #4 #3 #2 #1 #0
0134 NCD SYN PRY
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Bit
PRY Parity bit
0: Not used
1: Used
SYN Reset/alarm in protocol B
0: Not reported to the host
1: Reported to the host with SYN and NAK codes
NCD CD (signal quality detection) of the RS-232-C interface
0: Checked
1: Not checked
#7 #6 #5 #4 #3 #2 #1 #0
0135 RMS PRA ETX ASC
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Bit
ASC Communication code except NC data
0: ISO code
1: ASCII code
ETX End code for protocol A or extended protocol A
0: CR code in ASCII/ISO
1: ETX code in ASCII/ISO
NOTE
Use of ASCII/ISO is specified by ASC.
PRA Communication protocol
0: Protocol B
1: Protocol A
RMS State of remote/tape operation when protocol A is used
0: Always 0 is returned.