4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 270 -
NOTE
When rigid tapping is performed using the second
spindle
• When the SPR parameter (bit 1 of parameter
No.5204) is set to 1, the settings of parameters
No.5325 and No.5326 are applied to the second
spindle.
• When the SPR parameter (bit 1 of parameter
No.5204) is set to 0, the settings of parameters
No.5321 and No.5322 are applied to the second
spindle, as well as to the first spindle.
Time constant for the spindle and tapping axis in second spindle extraction
operation (first-stage gear)
5335
Time constant for the spindle and tapping axis in second spindle extraction
operation (second-stage gear)
5336
[Data type] Word
[Unit of data] ms
[Valid data range] 0 to 4000
Each of these parameters is used to set a linear
acceleration/deceleration time constant for the spindle and tapping
axis in extraction operation during rigid tapping on a gear-by-gear
basis.
NOTE
This parameter is enabled when both the TDR
parameter (bit 2 of parameter No.5201) and the
SPR parameter (bit 1 of parameter No.5204) are
set to 1.