B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 371 -
Example: When 8000 is set
8000: Parameters of group 0 (I/O channel = 20)
8001: Macro variables of group 0 (I/O channel = 20)
8002: Diagnostic data of group 0 (I/O channel = 20)
8010: Parameters of group 1 (I/O channel = 21)
8011: Macro variables of group 1 (I/O channel = 21)
8012: Diagnostic data of group 1 (I/O channel = 21)
8020: Parameters of group 2 (I/O channel = 22)
8021: Macro variables of group 2 (I/O channel = 22)
8022: Diagnostic data of group 2 (I/O channel = 22)
: :
8150: Parameters of group 15 (I/O channel = 35)
8151: Macro variables of group 15 (I/O channel = 35)
8152: Diagnostic data of group 15 (I/O channel = 35)
NOTE
1 When 0 is set, the input/output of parameters,
macro variables, and diagnostic data cannot be
performed, but program input/output processing is
performed.
2 When data is input from or output to the Power
Mate, setting data of I/O CHANNEL must also be
set.
8790 Timing for executing an auxiliary macro
[Data type] Word
[Unit of data]
This parameter sets the timing for executing a macro executor
auxiliary macro while NC programs, offset data, and so forth are being
read or punched out.
When as many characters as the number specified with this parameter
are read or punched out, an auxiliary macro is executed once. When 0
is set in this parameter, no auxiliary macro is executed during read or
punch processing.
#7 #6 #5 #4 #3 #2 #1 #0
8801
[Data type] Bit
Bit parameter 1 for machine tool builder