4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 354 -
SYC Spindle synchronization is:
0 : Not Used.
1 : Used.
SSN Serial spindle function is:
0: Used. (The analog spindle function is not used.)
1: Not Used. (The analog spindle function is used.)
NOTE
Spindle positioning and Cs contour control by the
serial spindle cannot be used at the same time.
#7 #6 #5 #4 #3 #2 #1 #0
CCR BAR IAP
8134
IAP
NOTE
When this parameter has been set, the power must
be turned off before operation is continued.
[Data type] Bit
IAP Conversational programming with graphic function is:
0 : Not Used.
1 : Used.
BAR Chuck and tail stock barrier function is:
0 : Not Used.
1 : Used.
CCR Chamfering / corner R is:
0 : Not Used.
1 : Used.
NOTE
When the chuck and tail stock barrier function is
selected, stored stroke limits 2 and 3 cannot be
used.