B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 391 -
4.59 PARAMETERS OF SERVO (2)
14010
Maximum permissible movement amount at FL feedrate when the reference
position is established with an encoder with the absolute address zero point
(detection circuit C)
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
This parameter sets the amount of a movement made at the FL
feedrate when the reference position is established with an encoder
with the absolute address zero point (linear scale or rotary encoder)
(detection circuit C). If the reference position is not established even
when a movement is made by the amount set in this parameter or more,
P/S alarm 5326 (Scale with the zero point: Failure in reference
position establishment) is issued. When this parameter is set to 0, the
maximum permissible movement amount at the FL feedrate at the
time of reference position establishment becomes invalid.
NOTE
1 When the reference position is established under
simplified synchronization control of the M series, if
this parameter is set for one of the master and
slave axes, the setting automatically applies also to
the other axis.
2 In angular axis control, the setting of this parameter
is invalid for a Cartesian axis with which angular
axis reference position is being established.