4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 382 -
12857 Number of a signal selected as an operation history signal (17)
12858 Number of a signal selected as an operation history signal (18)
12859 Number of a signal selected as an operation history signal (19)
12860 Number of a signal selected as an operation history signal (20)
[Data type] Word
[Valid data range] 0 to 511
Set the number of a signal of which operation history is to be recorded
for operation history channel (01) to (20) with a value between 0 and
511.
#7 #6 #5 #4 #3 #2 #1 #0
12881 RB7 RB6 RB5 RB4 RB3 RB2 RB1 RB0
History record bit settings for an operation history signal (01)
#7 #6 #5 #4 #3 #2 #1 #0
12882 RB7 RB6 RB5 RB4 RB3 RB2 RB1 RB0
History record bit settings for an operation history signal (02)
#7 #6 #5 #4 #3 #2 #1 #0
12883 RB7 RB6 RB5 RB4 RB3 RB2 RB1 RB0
History record bit settings for an operation history signal (03)
#7 #6 #5 #4 #3 #2 #1 #0
12884 RB7 RB6 RB5 RB4 RB3 RB2 RB1 RB0
History record bit settings for an operation history signal (04)
#7 #6 #5 #4 #3 #2 #1 #0
12885 RB7 RB6 RB5 RB4 RB3 RB2 RB1 RB0
History record bit settings for an operation history signal (05)
#7 #6 #5 #4 #3 #2 #1 #0
12886 RB7 RB6 RB5 RB4 RB3 RB2 RB1 RB0
History record bit settings for an operation history signal (06)