B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 205 -
3802 Maximum speed of the second spindle
[Data type] 2-word
[Unit of data] min
-1
[Valid data range] 0 to 32767
Parameter sets the maximum speed for the second spindle.
When a command specifying a speed exceeding the maximum speed
of the spindle is specified, or the speed of the spindle exceeds the
maximum speed because of the spindle speed override function, the
spindle speed is clamped at the maximum speed set in the parameter.
NOTE
1 This parameter is valid when the multi-spindle
control is selected.
2 When the constant surface speed control is
selected, the spindle speed is clamped to a
maximum speed, regardless of whether the G96
mode or G87 mode is set.
3 When this parameter is set to 0, parameter No.
3772 (maximum speed of the first spindle) is valid.
The spindle speed is not clamped when parameter
No. 3772 is set to 0.
4 When spindle speed command control is applied
using the PMC, this parameter has no effect, and
the spindle speed is not clamped.
3811 Maximum spindle speed for gear 1 of the second spindle
3812 Maximum spindle speed for gear 2 of the second spindle
[Data type] 2-word
[Unit of data] min
-1
[Valid data range] 0 to 32767
Set the maximum spindle speed for each gear of the second spindle.
NOTE
These parameters are used for the multi-spindle
control.