
4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 152 -
NDAx Position display using absolute coordinates and relative coordinates is:
0 : Performed.
1 : Not performed. (Machine coordinates are displayed.)
SFMx In current position display, subscripts are:
0 : Added to the absolute, relative, and machine coordinate axis
names.
1 : Assed only to the machine coordinate axis names.
NDFx To the actual speed display, axis movement data is:
0 : Added.
1 : Not added.
NOTE
Even if the PCF parameter (bit 1 of parameter
No.3105) is set to 0, so as to add PMC controlled
axis movement data to the actual speed display,
the movement data for a PMC controlled axis for
which NDFx is set to 1 is not added to the actual
speed display.
D10x The current positions (absolute position, relative position, machine
position, remaining travel, and travel by manual handle interrupt), and
workpiece zero-point offset are:
0 : Displayed as usual. (Not multiplied by ten.)
1 : Multiplied by ten, and displayed.
Example:
The current position on the Y-axis is multiplied by ten and
displayed.
X 1.2345 → X 1.2345
Y 1.2345 → Y 12.345
Z 1.2345 → Z 1.2345