B–63503EN–1/01
2. PREPARATIONS FOR OPERATION
108
[Completion code]
0: The load torque data was read normally.
4: Incorrect data was specified as a data attribute, that is a value other
than –1 or 1 to n (number of axes) was specified. Alternatively, a
value greater than the number of controllable axes was specified.
[Output data structure]
Top address + 0
(Function code)
211
(Completion code)
?
(Refer to the above description
about the completion code.)
(Data length)
L
(L = 2*n, where n is the num-
ber of specified axes)
(Data number)
0
(Data attribute)
M
(M: Data at input)
Load torque for the specified
axis (2 bytes)
Signed binary format (negative val-
ue in two’s complement)
Description of value
10
4
6
8
2
Or if there are four controllable axes
10
12
14
16
Load torque for the first axis
(2 bytes)
Load torque for the second
axis (2 bytes)
Load torque for the third axis
(2 bytes)
Load torque for the fourth axis
(2 bytes)
Signed binary format (negative val-
ue in two’s complement)
Description of value