B–63503EN–1/01
1. AXIS CONTROL
56
8311 Axis number of master axis in synchronous control
[Data type] Byte axis
[Valid data range] 0 to 4
Select a master axis for simple synchronous control. Set a master axis
number for the axis used as a slave axis. If the value of this parameter is
0, the first axis is the master axis. In this case, when the synchronous
control select signal G138 is set to 1, operation starts with the 1st axis
being the master axis.
Units digit in the parameter for the first axis
→ Set the master axis number for the first axis.
Tens digit in the parameter for the first axis
→ Set the master axis number for the second axis.
Units digit in the parameter for the second axis
→ Set the master axis number for the third axis.
Tens digit in the parameter for the second axis
→ Set the master axis number for the fourth axis.
Number Tens digit Units digit
First
Second
Second axis
Fourth axis
First axis
Third axis
NOTE
The axis number settings are: 0 for the first axis, 1 for the
second axis, 2 for the third axis, and so on.
Example) To set the 3rd axis to teh master axis and the 4th axis to the slave
axis, set as follows:
No. 8311
1st axis 00
2nd axis 20
3rd axis 00
4th axis 00
Parameter
T series