B–63503EN–1/01
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
255
[Data type] Two–word
Valid data range
y
IS-B IS-C
Millimeter machine 0.1 mm/min 6 – 150000 6 – 120000
Inch machine 0.01 inch/min 6 – 60000 6 – 48000
Rotation axis 0.1 deg/min 6 – 150000 6 – 120000
Set Feedrates for F1-digit feed commands F1 to F9.
When an F1-digit feed command is executed, as the feedrate is changed by
turning the manual pulse generator, these parameter values also change
accordingly.
1460 Upper limit of feedrate for the F1–digit feed command (F1 to F4)
1461 Upper limit of feedrate for the F1-digit feed command (F5 to F9)
[Data type] Two–word
Valid data range
y
IS-B IS-C
Millimeter machine 1 mm/min 6 – 15000 6 – 12000
Inch machine 0.1 inch/min 6 – 6000 6 – 4800
Rotation axis 1 deg/min 6 – 15000 6 – 12000
Set the upper limit of feedrate for the F1-digit feed command.
As the feedrate increases by turning the manual pulse generator, the
feedrate is clamped when it reaches the upper limit set. If an F1-digit feed
command F1 to F4 is executed, the upper limit is that set in parameter
1460. If an F1-digit command F5 to F9 is executed, the upper limit is that
set in parameter 1461.
OPERATOR’S MANUAL
(For Machining Center)
(B–63514EN)
Cutting feed
[Unit of data]
[Valid data range]
[Unit of data]
[Valid data range]
Reference item