B–63503EN–1/01
1. AXIS CONTROL
57
8312 Enabling/disabling mirror image in synchronous control
[Data type] Byte axis
[Valid data range] –128 to +127
This parameter sets the mirror image function. When 100 or a greater
value is set with this parameter, the mirror image function is applied to
synchronous control. Set this parameter to the slave axis.
Example: To establish reversed synchronization when using the third axis
as the master axis and the fourth axis as the slave axis, set parameter No.
8312 as follows:
Parameter No. 8312 (first axis) = 0
Parameter No. 8312 (second axis) = 0
Parameter No. 8312 (third axis) = 0
Parameter No. 8312 (fourth axis) = 100
#7 #6 #5 #4 #3 #2 #1 #0
SMF3105
[Data type] Bit
SMF During simple synchronous contorol, movement along a slave axis is:
0 : Included in the actual speed display
1 : Not included in the actual speed display
NOTE
This parameter is valid when simple syncronous contorol is
applied according to the setting of parameter No. 8311
(master and slave axes can be arbitrarily selected).
#7 #6 #5 #4 #3 #2 #1 #0
SOF8301
[Data type] Bit
SOF The synchronization compensation funciton under simple synchronous
control is:
0 : Not used.
1 : Used.
M series