B–63503EN–1/01
2. PREPARATIONS FOR OPERATION
73
WARNING
1 For axes with diameter specification, a diameter value must
be set.
2 When the parameters are set as follows, the stroke
becomes infinite:
parameter 1320 < parameter 1321
For movement along the axis for which infinite stroke is set,
only incremental commands are available. If an absolute
command is issued for this axis, the absolute register may
overflow, and normal movement will not result.
1326 Coordinate value II of stored stroke check 1 in the positive direction on each axis
1327 Coordinate value II of stored stroke check 1 in the negative direction each axis
[Data type] Two–word axis
Increment system IS–B IS–C Unit
Metric input 0.001 0.0001 mm
Inch input 0.0001 0.00001 inch
Rotation axis 0.001 0.0001 deg
[Valid data range] – 99999999 to 99999999
Set the coordinate values of stored stroke checks 1 in the positive and
negative directions for each axis in the machine coordinate system.
When stroke check switching signal EXLM is ON, stroke checks are
checked with parameters 1326 and 1327, not with parameters 1320 and
1321. The area outside that set by parameters 1326 and 1327 is inhibited.
NOTE
The EXLM signal is enabled only when LMS, #2 of
parameter 1300, is set to 1.
Number Message Description
500 OVER TRAVEL : +n Exceeded the n–th axis (axis 1–4) +
side stored stroke check 1.
501 OVER TRAVEL : –n Exceeded the n–th axis (axis 1–4) –
side stored stroke check 1.
CAUTION
In setting a forbidden area, if two points to be set are the
same, all area is forbidden in check 1.
[Unit of data]
Alarm and message
Caution