B–63503EN–1/01
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
267
These signals decelerate the feedrate of the control axes down to the speed
which has been set by parameter No. 1426 and 1427.
[Classification] Input signal
[Function] These signals are used to apply deceleration; provided for each direction
of each control axis; +/* indicates the direction, while the signal number
corresponds to the number of the controlled axis.
1 … The 1st axis is decelerated.
2 … The 2nd axis is decelerated.
3 … The 3rd axis is decelerated.
+ … The feed is decelerated in the plus (+) direction.
– … The feed is decelerated in the minus (–) direction.
ED+
*
[Operation] When a signal becomes “0”, the corresponding axis decelerate to stop in
the specified direction.
#7
G118
#6 #5 #4 #3
*+ED4
#2
*+ED3
#1
*+ED2
#0
*+ED1
G120 *–ED4 *–ED3 *–ED2 *–ED1
7.1.8
External Deceleration
General
Signal
External deceleration
signal
*+ED1 to *+ED4<G118>
*–ED1 to *–ED4<G120>
Signal address