B–63503EN–1/01
3. MANUAL OPERATION
118
1424 Manual rapid traverse rate for each axis
[Data type] Two–word axis
Valid data range
y
IS-B IS-C
Millimeter machine 1 mm/min 30 – 240000 30 – 100000
Inch machine 0.1 inch/min 30 – 96000 30 – 48000
Rotation axis 1 deg/min 30 – 240000 30 – 100000
Set the rate of manual rapid traverse when the rapid traverse override is
100% for each axis.
NOTE
If 0 is set, the rate set in parameter 1420 is assumed.
#7
1610
#6 #5 #4
JGLx
#3 #2 #1 #0
[Data type] Bit axis
JGLx Acceleration/deceleration in manual continuous feed (jog feed)
0: Exponential acceleration/deceleration is applied.
1: Linear acceleration/deceleration after interpolation is applied
(depending on which is used in cutting feed).
1624
Time constant of exponential acceleration/deceleration or bell–shaped
acceleration/deceleration or linear acceleration/deceleration after
interpolation, in jog feed for each axis.
[Data type] Word axis
[Unit of data] 1 msec
[Valid data range] 0 to 4000 (for exponential acceleration/deceleration)
0 to 512 (for linear acceleration/deceleration after interporation)
Set the time constant used for exponential acceleration/deceleration or
linear acceleration/deceleration after interpolation in jog feed for each
axis.
1625 FL rate of exponential acceleration/deceleration in jog feed for each axis
[Data type] Word axis
Valid data range
y
IS-B IS-C
Millimeter machine 1 mm/min 6 – 15000 6 – 12000
Inch machine 0.1 inch/min 6 – 6000 6 – 4800
Rotation axis 1 deg/min 6 – 15000 6 – 12000
Set the lower limit (FL rate) of exponential acceleration/deceleration in
jog feed for each axis.
[Unit of data]
[Valid data range]
[Unit of data]
[Valid data range]