15. PMC CONTROL FUNCTION
B–63503EN–1/01
756
NOTE
1 This parameter is valid when the DIAx bit (bit 3 of parameter
1006) is held 1.
2 When the CDI bit is set to 1, the NDI bit (bit 7 of parameter
8004) is invalid.
MFD : The miscellaneous function individual output of the PMC axis control
function is:
0 : Not effective.
1 : Effective.
8010 Selection of the DI/DO group for each axis controlled by the PMC
[Data type] Byte axis type
[Valid data range] 1 to 4
Specify the DI/DO group to be used to specify a command for each
PMC–controlled axis.
Value Description
1 DI/DO group A (G142 to G153) is used.
2 DI/DO group B (G154 to G165) is used.
3 DI/DO group C (G166 to G177) is used.
4 DI/DO group D (G178 to G189) is used.
NOTE
If another value is specified, the axis is not PMC–controlled.
8022 Maximum feedrate for feed per rotation along a PMC–controlled axis
[Data type] Word axis type
Valid data range
y
IS-B IS-C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Rotaion axis 1 deg/min 6 to 15000 6 to 12000
Specify the maximum feedrate for feed per rotation along a PMC–con-
trolled axis
NOTE
The maximum feedrate set to first axis is valid to all axes.
The data of after second axis are invalid.
[Unit of data]
[Valid data range]