4. REFERENCE POSITION ESTABLISHMENT
B–63503EN–1/01
134
[Classification] Output signal
[Function] Notify the system that the reference position has been established.
A reference position establishment signal is provided for each axis. The
number appended to each signal name indicates the number of the
controlled axis.
1 : 1st–axis reference position establishment signal
2 : 2nd–axis reference position establishment signal
3 : 3rd–axis reference position establishment signal
:
:
ZRF 1
[Output condition] The signals are set to 1 in the following case:
⋅ When the reference position is established after manual reference
position return
⋅ When the reference position is established using the absolute–position
detector at initial power–on
The signals are set to 0 in the following case:
⋅ When the reference position is lost
#7
*DEC8X1009
#6
*DEC7
#5
*DEC6
#4
*DEC5
#3
*DEC4
#2
*DEC3
#1
*DEC2
#0
*DEC1
ZRNG043
#7 #6 #5 #4 #3 #2 #1 #0
#7
MREFF004
#6 #5 #4 #3 #2 #1 #0
F094 ZP4 ZP3 ZP2 ZP1
F120 ZRF4 ZRF3 ZRF2 ZRF1
#7
1002
#6 #5 #4 #3 #2 #1 #0
JAX
[Data type] Bit
JAX Number of axes controlled simultaneously in JOG feed, manual rapid
traverse and manual reference position return
0 : 1 axis
1 : 3 axes
Reference position
establishment signal
ZRF1 to ZRF4<F120>
Signal address
Parameter