B–63503EN–1/01
1. AXIS CONTROL
58
8311 Axis number of master axis in synchronous control
[Data type] Byte axis
[Valid data range] 0 to 4
Select a master axis and slave axis for simple synchronous control. Set
a master axis number for the slave axis side.
Example: When using the first axis (X–axis) as the master axis, and the
third axis (Z–axis) as the slave axis, set parameter No. 8311 as follows:
Parameter No. 8311 X (first axis) = 0
Parameter No. 8311 Y (second axis) = 0
Parameter No. 8311 Z (third axis) = 1
Parameter No. 8311 A (fourth axis) = 0
Specifying the third axis (Z–axis) as the master axis, and the first axis
(X–axis) as the slave axis is not allowed. The master axis number must
always be smaller than the slave axis number.
It is impossible to specify more than one slave axis for a master axis.
Limit of the difference between the amount of positioning deviation of the master
and slave axes
8313
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 0 to 32767
This parameter specifies a limit imposed on the positional deviation
difference between the master and slave axes. If the limit is exceeded, a
P/S alarm (No. 213) is issued.