B–63503EN–1/01
5. AUTOMATIC OPERATION
169
[Classification] Output signal
[Function] Notifies the PMC that the CNC is being reset. This signal is used for reset
processing on the PMC.
[Output condition] This signal is set to 1 in the following cases:
1. When the emergency stop signal (*ESP) is set to 0
2. When the external reset signal (ERS) is set to 1
3. When the reset & rewind signal (RRW) is set to 1
4. When MDI RESET key is pressed
This signal is set to 0 in the following case:
When the resetting signal output time, set with parameter No. 3017, has
elapsed after the above conditions have been released and the CNC is reset
[Classification] Output signal
[Function] Notifies the PMC that the CNC is being rewound.
[Output condition] As described in the item, “Reset and Rewind”.
#7 #6 #5 #4 #3 #2 #1 #0
G008
F000
F001
ERS RRW
RWD
RST
#7 #6 #5 #4 #3 #2 #1 #0
#7 #6 #5 #4 #3 #2 #1 #0
3001 RWM
[Data type] Bit
RWM RWD signal indicating that rewinding is in progress
0 : Output only when the tape reader is being rewound by the reset and
rewind signal RRW
1 : Output when the tape reader is being rewound or a program in
memory is being rewound by the reset and rewind signal RRW
Resetting signal RST
<F001#1>
Rewinding signal RWD
<F000#0>
Signal address
Parameter