B–63503EN–1/01
1. AXIS CONTROL
54
[Classification] Input signal
[Function] synchronous control is performed for memory or MDI operation.
The signal is provided for each controlled axis. The number at the end
of the signal name represents the number of the controlled axis.
1. ... The first axis becomes the slave axis for synchronous control.
2. ... The second axis becomes the slave axis for synchronous control.
3. ... The third axis becomes the slave axis for synchronous control.
:
:
SYNC 1
[Operation] When the signal is set to 1, the control unit operates as described below:
– During memory or MDI operation, the control unit supplies the move
command, specified for the master axis, to both the master and slave
axes of synchronous control.
The master axis is specified with a parameter.
[Classification] Input signal
[Function] synchronous control is performed in jog, handle, or incremental feed
mode.
The signal is provided for each controlled axis. The number at the end
of the signal name represents the number of the controlled axis.
1. ... The first axis becomes the slave axis for synchronous control.
2. ... The second axis becomes the slave axis for synchronous control.
3. ... The third axis becomes the slave axis for synchronous control.
:
:
SYNCJ 1
[Operation] When the signal is set to 1, the control unit operates as described below:
Signal
<T series and
M series>
Signals to select the
slave axis for simple
synchronous control
SYNC1 to SYNC4 <G138>
<M series>
Signals for selecting the
manual feed axis for
simple synchronous
control
SYNCJ1 to SYNCJ4
<G140>