B–63503EN–1/01
11. PROGRAM COMMAND
599
5411 Magnification used when scaling magnification is not specified
Setting entry is acceptable.
[Data type] Two–word
[Unit of data] 0.001 or 0.00001 times (Selected using SCR, #7 of parameter No. 5400)
[Valid data range] 1 to 999999
This parameter sets the scaling magnification. This setting value is used
when a scaling magnification (P) is not specified in the program.
NOTE
Parameter No. 5421 becomes valid when scaling for every
axis is valid. (XSC, #6 of parameter No. 5400 is “1”.)
5421 Scaling magnification for every axis
[Data type] Two–word axis
[Unit of data] 0.001 or 0.00001 times (Selected using SCR, #7 of parameter No. 5400)
[Valid data range] *999999X*1, 1X999999
This parameter sets the scaling magnification for every axis.
Number Message Description
141 CAN NOT COMMAND
G51 IN CRC
G51 (Scaling ON) is commanded in the
tool offset mode.
Modify the program.
142 ILLEGAL SCALE RATE Scaling magnification is commanded in
other than 1 – 999999.
Correct the scaling magnification set-
ting (G51 P
p
, or parameter 5411 or
5421).
143 SCALED MOTION DATA
OVERFLOW
The scaling results, move distance,
coordinate value and circular radius ex-
ceed the maximum command value.
Correct the program or scaling magnifi-
cation.
OPERATOR’S MANUAL (For Machining
Center) (B–63514EN)
Scaling (G50, G51)
D Magnification used when
scaling magnification is
not specified
D Scaling magnification for
every axis
Alarm and message
Reference item