B–63503EN–1/01
9. SPINDLE SPEED FUNCTION
512
where
Pi = 0 when SHAi = 0
Pi = 1 when SHAi = 1
#7 #6 #5 #4 #3 #2 #1 #0
SHA07G078 SHA06 SHA05 SHA04 SHA03 SHA02 SHA01 SHA00
G079 SHA11 SHA10 SHA09 SHA08
SHB07G080 SHB06 SHB05 SHB04 SHB03 SHB02 SHB01 SHB00
G081 SHB11 SHB10 SHB09 SHB08
#7 #6 #5 #4 #3 #2 #1 #0
3702 OR2 OR1
[Data type] Bit
OR1 Whether the stop–position external–setting type orientation function is
used by the first spindle motor
0 : Not used
1 : Used
OR2 Whether the stop–position external–setting type orientation function is
used by the second spindle motor
0 : Not used
1 : Used
CAUTION
1 To perform spindle orientation by using the spindle control
unit, the signals of the spindle control unit must be used.
To perform serial spindle orientation by using a position
coder (to perform serial spindle orientation with the stop
position set externally), the serial spindle control unit signals
must be used.
2 When the spindle orientation function of stop position
external setting type is used, the stop position parameters
in spindle orientation with a position coder (No. 4031 and
4204) are invalid.
NOTE
Spindle orientation with the spindle positioning function
differs from that described in this section. For details, see
Section 9.7, “Spindle Positioning.”
Signal address
Parameter
Caution
Note