B–63503EN–1/01
15. PMC CONTROL FUNCTION
731
D Maximum feedrate (with override of 254%)
IS–B IS–C
Metric input Inch input Metric input Inch input
Magnified
by 1
166458mm/
min
1664.58inch/
min
16645mm/min 166.45inch/
min
Magnified
by 10
1664589mm/
min
16645.89
inch/min
166458mm/
min
1664.58inch/
min
IS–B IS–C
Metric input Inch input Metric input Inch input
Magni-
fied by 1
65535mm/
min
655.35inch/
min
6553mm/min 65.53inch/
min
Magni-
fied by
10
655350mm/
min
6553.50inch/
min
65535mm/
min
655.35inch/
min
(15) Speed command (EC0g to EC6g: 10h)
For this command, the signals are used to specify, in binary format,
the servo motor speed.
Specify a positive value for rotation in the forward direction.
Specify a negative value (twos complement) for rotation in the
reverse direction.
When a new servo motor speed is specified, inverting the axis
control command read signal EBUFg accelerates or decelerates the
servo motor until it attains the new speed.
Data range Unit
–32768 to +32767 min
–1
NOTE
The servo motor speed may contain a slight error, as
follows:
Gears
↑
Motor
Axis
Detector
(a)
(b)
Speed command
Amplifier
↑
CAUTION
The maximum feedrate depends on whether override is
applied or canceled. The following table lists the maximum
feedrate when override is canceled.