15. PMC CONTROL FUNCTION
727
Operation Command data
Axis control code
signal EC0g to EC6g
Torque control 11h Maximum feedrate,
EIF0g to EIF15g
Torque data, EID0g to
EID31g
Auxiliary function 12h Auxiliary function code
EID0g to EID15g
Miscellaneous function
2
14h Miscellaneous function
code, EID0g to EID15g
Miscellaneous function
3
15h Miscellaneous function
code, EID0g to EID15g
Machine coordinate
system setting
20h Machine coordinate
system setting
(absolute value)
EID0g to EID31g
Rapid traverse rate
EIF0g to EIF15g
The rapid traverse rate
setting is effective when
bit 0 (RPD) of parameter
No. 8002 is set to “1”.
[Classification] Input signal
[Function] (1) Rapid traverse (EC0g to EC6g: 00h)
(2) 1st reference position return (EC0g to EC6g: 07h)
(3) 2nd reference position return (EC0g to EC6g: 08h)
(4) 3rd reference position return (EC0g to EC6g: 09h)
(5) 4th reference position return (EC0g to EC6g: 0Ah)
(6) Machine coordinate system selection (EC0g to EC6g: 20h)
For these commands, signals EIF0g to EIF15g are used to specify
the rapid traverse rate, in binary format, when bit 0 (RPD) of
parameter No. 8002 is set to “1”. For 1st reference position return,
however, the rapid traverse rate specified with parameter No. 1424
is used if manual reference position return has not been performed
after the power was first turned on.
Data unit
IS–B IS–C
Unit
Linear
Metric machine 1 mm/min
axis
Inch machine 0.1 inch/min
Rotation axis 1 deg/min
3 Axis control feedrate
signals EIF0g to
EIF15g
[Unit of data]