B–63503EN–1/01
9. SPINDLE SPEED FUNCTION
356
#7 #6 #5 #4 #3 #2 #1 #0
400 SAI SS2 SSR POS SIC
SIC 0: No module is available for spindle serial output.
1: A module for spindle serial output is available.
POS 0: No module is available for spindle analog output.
1: A module for spindle analog output is available.
SSR 0: Spindle serial output is not used.
1: Spindle serial output is used.
SS2 0: The second spindle is not used with spindle serial output.
1: The second spindle is used with spindle serial output.
SAI 0: Spindle analog output is not used.
1: Spindle analog output is used.
401 Alarm condition for the serial spindle unit for the first spindle (AL–??)
402 Alarm condition for the serial spindle unit for the second spindle (AL–??)
#7 #6 #5 #4 #3 #2 #1 #0
SSA408 SCA CME CER SNE FRE CRE
CRE 1 : CRC error (warning)
FRE 1 : Framing error (warning)
SNE 1 : Mismatch between sending and receiving sections
CER 1 : Abnormal reception
CME 1 : No answer during auto scanning
SCA 1 : Communication error in the spindle amplifier
SSA 1 : System error in the spindle amplifier
(These errors are reflected in spindle alarm 749. They are caused by noise,
disconnection, or instantaneous power interruption.)
#7 #6 #5 #4 #3 #2 #1 #0
409 SPE S2E S1E SHE
SHE 1 : Abnormal operation in the serial spindle communication module of
the CNC
S1E 1 : Abnormal operation on the first spindle during activation
S2E 1 : Abnormal operation on the second spindle during activation
SPE 1 : Serial spindle parameter not meeting activation conditions
(These errors are reflected in spindle alarm 750.)
DIAGNOSIS SCREEN
D Information on spindle
control
D Communication error on
spindle serial output
interface
D Information related to the
activation of the spindle
serial output interface