12. DISPLAY/SET/EDIT
B–63503EN–1/01
656
The password function locks NE9 (bit 4 of parameter No. 3202), used to
protect program Nos. 9000 to 9999, by using the PASSWD (No. 3210)
and KEYWD (No. 3211) parameters. When NE9 is locked, NE9 cannot
be set to 0. Therefore, the protection for programs numbered 9000 to 9999
cannot be released unless the correct keyword is entered.
NE9 is locked when different values are set in the PASSWD and KEYWD
parameters. The values set in the two parameters are not displayed. NE9
is unlocked when the value preset in the PASSWD parameter is set in the
KEYWD parameter. When 0 is indicated for the PASSWD parameter, a
value has not yet been set for PASSWD.
#7 #6 #5 #4 #3 #2 #1 #0
3202 NE9
[Data type] Bit
NE9 Editing of subprograms with program numbers 9000 to 9999
0 : Not inhibited
1 : Inhibited
The following edit operations are disabled:
(1)Program deletion (Even when deletion of all programs is specified,
programs with program numbers 9000 to 9999 are not deleted.)
(2)Program output (Even when outputting all programs is specified,
programs with program numbers 9000 to 9999 are not output.)
(3)Program number search
(4)Program editing after registration
(5)Program registration
(6)Program collation
(7)Displaying programs
12.2.4
Password Function
General
Parameter