B–63503EN–1/01
2. PREPARATIONS FOR OPERATION
79
Parameter LZR (bit 6 of No. 1300) selects whether each check becomes
effective after the power is turned on and manual reference position return
or automatic reference position return by G28 has been performed or
immediately after the power is turned on.
After the power is turned on, if the reference position is in the forbidden
area of each check, an alarm is generated immediately (Only in G22 mode
for stored stroke check 2).
When the tool enters and forbidden area and an alarm is generated, the tool
can be moved in the reverse direction from which the tool came. Please
move the tool out of the forbidden area, then please release the alarm by
reset. If succeeded, the tool become movable to both paths.
When G23 is switched to G22 in the forbidden area, the following results.
(1)When the forbidden area is inside, an alarm is informed in the next
move.
(2)When the forbidden area is outside, an alarm is informed immediately.
[Classification] Input signal
[Function] Selects whether stored stroke check 3 is checked.
[Use] When this signal is set to 1, the control unit operates as follows:
· The control unit does not check stored stroke check 3.
RLSOT3
#7
G007
#6 #5 #4 #3 #2 #1 #0
#7
BFA1300
#6
LZR
#5
RL3
#4 #3 #2 #1 #0
OUT
BFA LZK OUT
[Data type] Bit
OUT The area inside or outside of the stored stroke check 2 is set as an
inhibition area.
0: Inside
1: Outside
RL3 Stroke check 3 release signal RLSOT3
0: The signal is disabled.
1: The signal is enabled.
D Effective time for a
forbidden area
D Releasing the alarms
D Change from G23 to
G22 in a forbidden area
Signal
Storoke check 3 release
signal RLSOT3
<G007#4> (T series)
Signal address
Parameter