B–64113EN–1/01
15. PMC CONTROL FUNCTION
1007
The maximum feedrate in torque control mode can be changed in
torque control mode by setting the new feedrate data in the signal
then inverting the logic of axis control command read signal
EBUFg.
Valid data range Units
1 to 32767 min
–1
NOTE
The data units will be cm/min when a linear motor is being
used.
[Classification] Input signal
[Function]
IS–B IS–C Unit
Metric input
Degree input
0.001 0.0001 mm
deg
Inch input 0.0001 0.00001 inch
[Valid data range]
(1) Rapid traverse (EC0g to EC6g: 00h)
(2) Cutting feed – feed per minute (EC0g to EC6g: 01h)
(3) Cutting feed – feed per rotation (EC0g to EC6g: 02h)
(4) Skip – feed per minute (EC0g to EC6g: 03h)
For these commands, signals EID0g to EID31g are used to specify, in
binary format, the incremental moving distance, according to the input
increment used for the axis.
IS–B IS–C Unit
Metric input
Degree input
"99999.999 "9999.9999 mm
deg
Inch input "9999.9999 "999.99999 inch
When diameter programming is specified with bit 3 (DIAx) of parameter
No. 1006, bit 1 (CDI) of parameter No. 8005 can be used to specify
whether a radius or diameter is to be used in a command.
4 Axis control data
signals
EID0g to EID31g
[Unit of data]