B–64113EN–1/01
12. DISPLAY/SET/EDIT
841
#7 #6 #5 #4 #3 #2 #1 #0
MS13113 MS0 MHC
MHC External operator message history data:
0 : Cannot be cleared.
1 : Can be cleared.
(Such data can be cleared using the [CLEAR] soft key.)
MS0, MS1 Set the number of items and the item length.
MS1 MS0 Number of history
data characters
Number of history
data items
0 0 255 8
0 1 200 10
1 0 100 18
1 1 50 32
CAUTION
When the values of MS0 and MS1 are changed, all
preserved external operator message history data is
cleared.
#7
3207
#6 #5 #4 #3 #2 #1 #0
OM4
[Data type] Bit
OM4 A message displayed on the external operator message screen can have:
0 : Up to 256 characters, and just a single message can be displayed.
1 : Up to 64 characters, and up to four messages can be displayed.
OPERATOR’S MANUAL
(M series) (B–64124EN)
III.11.7.1
External operator message log-
ging and display
OPERATOR’S MANUAL
(T series) (B–64114EN)
III.11.7.1
External operator message log-
ging and display
OPERATOR’S MANUAL
(M series) (B–64144EN)
III.11.7.1
External operator message log-
ging and display
OPERATOR’S MANUAL
(T series) (B–64134EN)
III.11.7.1
External operator message log-
ging and display
Reference item